Wired and modular systems to implement your system whenever you want with extreme ease
Wired and modular systems to implement your system whenever you want with extreme ease
Expanding the system with additional components has never been easier
A success that has lasted for 40 years
Possibility of managing zone partitioning via integrated electronic key, local keyboard or remote console
The freedom of management from an additional console of minimal size and modern design
Systems that allow total optimization and coverage of every area of the entire plant
TM600GSM | |
---|---|
![]() | |
Built-in GSM dialer | zone identifier, remote self-exclusion |
GSM module | Quad band |
Degree of security | 1 |
Environmental class | 2 |
Control LED | network presence, exit time, alarm status, zone status, alarm memory |
"24h" anti-sabotage protection zones | 1 |
Protection zones | 6 (4 immediate + 2 delayed) |
Rated supply voltage | 230V~ ±5% 50Hz |
Balanced zones | 2 |
Nominal service output voltage | 12Vdc ±10% |
Battery compartment in buffer | (Recommended battery 12V7.5Ah) |
Adjustable alarm duration | 180 - 600sec |
Degree of protection of the container | IP30 |
Adjustable exit time | 4 - 75sec |
Adjustable entry time | 4 - 75sec |
Container | metallic |
Operating temperature | +5°C - +40°C |
Dimensions (L) | 285mm |
Dimensions (H) | 228mm |
Dimensions (W) | 95mm |
Modular anti-theft systems that allow coverage of 5 to 8 zones
TM500P | TM900P | |
---|---|---|
![]() ![]() | ![]() ![]() | |
Degree of security | 1 | 1 |
Environmental class | 2 | 2 |
Control LED | network presence, exit time, alarm status, zone status, alarm memory | network presence, exit time, alarm status, zone status, alarm memory |
Immediate protection zones | 4 | 7 |
Delayed protection zones | 1 | 1 |
"24h" anti-sabotage protection zones | 1 | 1 |
Rated supply voltage | 12Vdc ±10% | 12Vdc ±10% |
Nominal service output voltage | 12Vdc ±10% | 12Vdc ±10% |
Normal absorption | 50mA | 50mA |
Maximum absorption | 140mA | 140mA |
Maximum absorption of the power plant alone | 35mA | 35mA |
Maximum current that can be delivered at the siren output | 3A (with battery connected) | 3A (with battery connected) |
Maximum current that can be supplied at service output | 650mA | 650mA |
Adjustable alarm duration | 180 ÷ 600sec. | 180 ÷ 600sec. |
Fuse on the transformer primary | 250mA L 250V type F | 250mA L 250V type F |
Fuse on the transformer secondary | 2A L 250V type F | 2A L 250V type F |
Sounders output fuse | 3A rapid type 5x20mm | 3A rapid type 5x20mm |
Services power supply output fuse | 1A rapid type 5x20mm | 1A rapid type 5x20mm |
Get out | Ext/Int siren activation, positive present when system is armed, relay output on alarm | Ext/Int siren activation, positive present when system is armed, relay output on alarm |
Adjustable exit time | 5 ÷ 90 sec. | 5 ÷ 90 sec. |
Adjustable entry time | 5 ÷ 90 sec. | 5 ÷ 90 sec. |
Container | iron | iron |
Operating temperature | +5°C ÷ +40°C | +5°C ÷ +40°C |
Dimensions (L) | 285mm | 285mm |
Dimensions (H) | 95mm | 95mm |
Dimensions (W) | 17mm | 17mm |
TM96P | TM66GSM | TM26GSM | |
---|---|---|---|
![]() ![]() | ![]() ![]() | ![]() ![]() | |
SMS messages (128 characters) | 6 | 2 | |
TXT messages (16 characters) for checking the status of the inputs and outputs | 28 | 2 | |
Programmable codes: MASTER Code and COMMAND Code | 2 | 2 | 2 |
Channels | 2 | 6 | 2 |
Degree of security | 1 | 1 | 1 |
Environmental class | 2 | 2 | 2 |
Programming menu | Italian, English, French, German, Spanish, Portuguese | Italian, English, French, German, Spanish, Portuguese | Italian, English, French, German, Spanish, Portuguese |
Rated supply voltage | 12Vdc ±10% | 12Vdc ±10% | 12Vdc ±10% |
Maximum absorption | 180mA | 400mA | 400mA |
Standby power consumption | 40mA | 70mA | 70mA |
Voice messages (16 sec.) | 3 | 7 | 3 |
Voice messages (2 sec.) to check the input and output states | 2 | 8 | 2 |
Address book | 16 numbers | 16 numbers | 16 numbers |
Antenna | ANTGSM4 included | ANTGSM4 included | |
GSM module | Quad band | Quad band | |
Inputs programmable in pulse or state mode, conditionable on the other inputs | 2 | 6 | 2 |
INT conditionable inputs | 2 | 2 | 2 |
Programmable changeover relay outputs | 1 | 1 | 1 |
Open collector outputs | 1 | 5 | 1 |
Container | metallic | metallic | metallic |
Dimensions (L) | 285mm | 285mm | 285mm |
Dimensions (H) | 95mm | 95mm | 95mm |
Dimensions (W) | 17mm | 17mm | 17mm |
Cookie | Durata | Descrizione |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |